Heat-Cold Chambers (CTH)

We manufacture modern equipment for testing in various climatic conditions in series or in accordance with the customer's specifications.

Order equipment
Heat-Cold Chambers (CTH)
  • Temperature range from -70ºC to + 150ºC
  • Temperature control accuracy: 1ºC
  • Automated control system (Thermadat | SAMWONTEC | OMRON)
  • Viewing window
  • Technological hole with a diameter of 100 mm
  • Possibility to move on built-in support rollers
Characteristics of production models
CHARACTERISTICS KTH-60М KTH-60М KTH-150 KTH-300 KTH-500 KTH-800 KTH-1000 KTH-2000
Chamber volume, l 64 64 150 300 500 800 1000 2000
Useful volume size, WxHxD, mm 400x400x400 400x400x400 500х500х600 600х700х700 800х800х800 900х900х1000 1000х1000х1000 1000х1300х1500
Overall dimensions, WxHxD, mm 750x900x 1080 750х1650 х800 800х1750 х1050 980х1750 х1500 1250х2100 х1850 1400х2100 х2000 1450х2200 х2100 1400х2300 х2700
Temperature range, ºC -40...+150 -70...+150 -70...+150 -70...+150 -70...+150 -70...+150 -70...+150 -70...+150
Temperature maintenance accuracy, ºC ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1
Viewing window
Technological hole, mm 100 100 100 100 100 100 100 100
Mains voltage 220V/50Hz/1F 380V/50Hz/3F 380V/50Hz/3F 380V/50Hz/3F 380V/50Hz/3F 380V/50Hz/3F 380V/50Hz/3F 380V/50Hz/3F

We can manufacture equipment according to your technical specifications

 

Description of the equipment of the KTH series

 

The heat-cold chamber is designed for testing in conditions of low and high temperatures, as well as when changing temperatures: from -70 to +150 ˚C.
Structurally, the chamber consists of a body on which heating and cooling systems are installed, as well as a working volume and an electrical panel. The camera is equipped with support rollers for movement.
The cooling system is a two-stage refrigeration machine based on semi-hermetic reciprocating compressors, only modern ozone-safe refrigerants are used. Cooling of the chiller can be either air or water.
The working volume is made of high quality stainless steel, the inner walls have a mirror-polished surface. The loading of the test samples is carried out through a swing door equipped with an observation window. As standard, the chamber has one process opening on the right or left side.
Test management is carried out by means of an automated control system based on a programmable logic controller (Termodat / SAMWONTEC / OMRON).
Optionally, the heat-cold chamber can be equipped with removable shelves, a control computer and additional technological openings.

Do you want to buy a serial KTH model or order according to your own technical specifications?

Leave your details and our manager will contact you and agree on the terms of reference

Order equipment

We provide warranty and post-warranty service for testing equipment.