Characteristics of production models

TEST CABIN SPECIFICATIONS

Salt and Cyclic CorrosionBooths

TestStandard Salt Spray

Booth

 

T450KS

T1300KS

T2000KS

Plus Saline Spray

Cab

 

T450KP

T1300KP

T2000KP

Cyclic Corrosion

Cab

 

CK450KP CK1300KP

CK2000KP

Cab

capacity

 

450 liters.

1300 liters.

2000 liter.

Cab weight

(approx., Selectable accessories

excluded.)

 

190 kg

285 kg

330 kg

Mounting format

ground

mounted groundground

mountedmounted

Installation threshold

 

800 mm

800 mm

800 mm

External dimensions of the car max.

 

W: 1660 mm

D: 840 mm

: 1510 mm

HW: 2025 mm

D: 1156

mm1906 mm

H:W: 2885 mm

D: 1145 mm H

: 1720 mm

Car interior dimensions

max.

 

W: 1010 mm

D: 640 mm

: 1140 mm

HW: 1300 mm

D: 980

mm1528 mm

H:W: 2160 mm

D: 980 mm H

: 1320 mm

Outside dimensions of the brine tank

 

W: 460 mm

D: 620 mm

: 675 mm

HW: 560 mm

D: 620 mm

: 675 mm

HW: 560 mm

D: 620 mm H

: 675 mm

Capacity of the brine tank

(for refill, see GLS02 for additional accessories )

 

80 liters.

115 liters.

115 liters.

Sample with removablegroove

RashariShelves placed

6 pieces of racks

8 pieces of racks

16 pieces of racks

on the upper level of the cabin

 

28 corner slots

 

The slot, each 3 mm (1/8 inch) wide, is angled 15 degrees from the vertical position.

 

46 corner slots

 

The slot, each 3 mm (1/8 inch) wide, is angled 15 degrees from the vertical position.

 

46 corner slots

 

The slot, each 3 mm (1/8 inch) wide, is angled 15 degrees from the vertical position.

 

Cabin structure

 

Plastic, PP and PVC parts with glass backing

 

Plastic, PP and PVC parts with glass backing

 

Plastic, PP and PVC parts with glass backing

 

Power Supply Standard Salt Spray Models

 

1 Phase

1 Phase

1 Phase

Plus

Salt Spray Models

 

1 Phase

1 Phase

3 Phase

CKT Models

3 Phase

Voltage (VAC) and frequency (Hz) vary by country / region.

 

3 phase

Voltage (VAC) and frequency (Hz) vary by country / region.

 

3 phase

Voltage (VAC) and frequency (Hz) vary by country / region.

 

Water

 

Separate and continuous deionized / clean water connection is required each at 0.5-5.0 bar (7.3-73 psi) to fill the saturation block, conduct moisture tests, and prepare salt water solution ...

Separate and continuous deionized / clean water connection is required each at 0.5-5.0 bar (7.3-73 psi) to fill the saturation block, conduct moisture tests, and prepare salt water solution ...

Separate and continuous deionized / clean water connection is required each at 0.5-5.0 bar (7.3-73 psi) to fill the saturation block, conduct moisture tests, and prepare salt water solution ...

air

clean dry and oil-free air at 4.0-6.0 bar (58-87 psi) and 240 liters (8.5 cc per minute ft (cu.ft))flow

cleandry and oil-free air at 4.0-6.0 bar (58-87 psi) and 240 liters (8.5 cc per minute ft (cu.ft)) flow

clean dry and oil-free air at 4.0-6.0 bar (58-87 psi) and 240 liters (8.5 cc per minute ft (cu.ft))flow

Exhaust

 

A 3 m (10 ft) exhaust pipe that must extend outside the building is supplied with the cab.

A 3 m (10 ft) exhaust pipe that must extend outside the building is supplied with the cab.

A 3 m (10 ft) exhaust pipe that must extend outside the building is supplied with the cab.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST

CABIN SPECIFICATIONS Atmosfarcabins Atmosfar

testtest benches Product code:

ATM1300KP / 1

ATM1300KP / 2

ATM2600KP / 1

ATM2600KP / 2

Minimum controlled temperature

-20° С

-40° С

-20° С

-40° С

capacity

.

1300 liters.

2600 liters.

2600 liters.

Cab weight (approx., Selectable accessories

excluded.)

 

340 kg

340 kg

440 kg

440 kg

Mounting format

 

mounted on the ground

mounted on the ground

mounted on the ground

mounted on the ground

Installation threshold

 

800 mm

800 mm

800 mm

800 mm

External dimensions of the car max.

 

W: 2025 mm

D: 1316 mm

: 1965 mm

HW: 2025 mm

D: 1316 mm

: 1965 mm

HW: 2885 mm

D: 1316

mm1965 mm

H:W: 2885 mm

D: 1316 mm H

: 1965 mm

Internal dimensions cabins max.

 

W: 1300 mm

D: 980 mm

: 1500 mm

HW: 1300 mm

D: 980 mm

: 1500 mm

HW: 2160 mm

D: 980

mm1500 mm

H:W: 2160 mm

D: 980 mm H

: 1500 mm

Cooling unit is a separate air conditioning unit located on the back or left side of the cabinet.

W 1510 mm

D: 1550

mm1055 mm

W 1510 mm

D: 1550

mm1055 mm

W 1510 mm

D: 1550

mm1055 mm

W 1510 mm

D: 1550

mm1055 mm

tank Brine solution 115 Ltrs is a separate unit and is fed to supply salt water to a traditional salt spray gun.

W: 560 mm

D: 620 mm

H: 675 mm

W: 560 mm

D: 620 mm

H: 675 mm

W: 560 mm

D: 620 mm

H: 675 mm

W: 560 mm

D: 620 mm

H: 675 mm

racks samples with removable slots

8pcs. racks

8pcs. racks

16pcs. racks

16pcs. racks

Shelves located on the bottom level of the cabinet

24 corner slots

Slots for shelving of various widths (up to 6 mm / 0.25 inches) have slots for shelving and a handle for carrying at different angles (up to 20 °).

24 corner slots

Slots for shelving in various widths (up to 6 mm / 0.25 inches) have slots for shelving and a handle for carrying at different angles (up to 20 °).

24 corner slots

Slots for shelving in various widths (up to 6 mm / 0.25 inches) have slots for shelving and a handle for carrying at different angles (up to 20 °).

24 corner slots

Slots for shelving in various widths (up to 6 mm / 0.25 inches) have slots for shelving and a handle for carrying at different angles (up to 20 °).

Cabin structure

 

Plastic, PP and PVC parts with glass backing

 

Plastic, PP and PVC parts with glass backing

 

Plastic, PP and PVC parts with glass backing

 

Plastic, PP and PVC parts with glass backing

 

The power supply

requires two 3-phase electrical connections (one for the cab and the other for the air conditioning unit). Voltage (VAC) and frequency (Hz) must vary by region / country and must be confirmed at the time of ordering.

two 3-phase electrical connections are required (one for the cab and the other for the air conditioning unit). Voltage (VAC) and frequency (Hz) must vary by region / country and must be confirmed at the time of ordering.

two 3-phase electrical connections are required (one for the cab and the other for the air conditioning unit). Voltage (VAC) and frequency (Hz) must vary by region / country and must be confirmed at the time of ordering.

two 3-phase electrical connections are required (one for the cab and the other for the air conditioning unit). Voltage (VAC) and frequency (Hz) must vary by region / country and must be confirmed at the time of ordering.

Water

To fill the saturation block, moisture and salt water tests are

required at 0.5-5.0 bar (7.3-73 psi), each separately and continuously

requires deionized / pure water.

To fill the saturation block, moisture and salt water tests are

required at 0.5-5.0 bar (7.3-73 psi), each separately and continuously

requires deionized / pure water.

To fill the saturation block, moisture and salt water tests are

required at 0.5-5.0 bar (7.3-73 psi), each separately and continuously

requires deionized / pure water.

To fill the saturation block, moisture and salt water tests are

required at 0.5-5.0 bar (7.3-73 psi), each separately and continuously

requires deionized / pure water.

Air

Clean dry and oil-free air at 4.0-6.0 bar (58-87psi) and 240 L (8.5 cfm) ft) flow. Two separate connections (one for the cabin, the otherbrine

for the reservoir) are required.

Clean dry and oil-free air at 4.0-6.0 bar (58-87psi) and 240 L (8.5 cfm) ft) flow. Two separate connections (one for the cabin, the otherbrine

for the reservoir) are required.

Clean dry and oil-free air at 4.0-6.0 bar (58-87psi) and 240 L (8.5 cfm) ft) flow. Two separate connections (one for the cabin, the otherbrine

for the reservoir) are required.

Clean dry and oil-free air at 4.0-6.0 bar (58-87psi) and 240 L (8.5 cfm) ft) flow. Two separate connections (one for the cabin, the otherbrine

for the reservoir) are required.

Exhaust

A 3 m (10 ft) exhaust pipe that must extend outside the building is supplied with the cab.

A 3 m (10 ft) exhaust pipe that must extend outside the building is supplied with the cab.

A 3 m (10 ft) exhaust pipe that must extend outside the building is supplied with the cab.

A 3 m (10 ft) exhaust pipe that must extend outside the building is supplied with the cab.

Drain

A 3 m (10 ft) drain pipe that will be attached to the base drain is supplied with the cabinet.

A 3 m (10 ft) drain pipe that will be attached to the base drain is supplied with the cabinet.

A 3 m (10 ft) drain pipe that will be attached to the base drain is supplied with the cabinet.

A 3 m (10 ft) drain pipe that will be attached to the base drain is supplied with the cabinet.

Working environment conditions

Indoors, in a protected environment from +18 to + 23 ° C, with a maximum relative humidity of 85% (not deconstructed).

Indoors, in a protected environment from +18 to + 23 ° C, with a maximum relative humidity of 85% (not deconstructed).

Indoors, in a protected environment from +18 to + 23 ° C, with a maximum relative humidity of 85% (not deconstructed).

Indoors, in a protected environment from +18 to + 23 ° C, with a maximum relative humidity of 85% (not deconstructed).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONAL TEST CABIN ACCESSORIES

Function

Item Code

Definition

Remarks

Renault D17 2028 (ECC-1)

fortesting

GLS01/ select below1000l

Kit with all necessary items for ECC-1

compatibility Only compatible with Renault approvedcabins

0 ° C e in environments

·         F *

GLS01 / 1

 


GLS01 / 2

GLS80 / 2 and GLS90 / 2 Options included

GLS112 / 2 and GLS112 / INT / 2 Options included

Not compatible for use with option GLS46.

 

-20 ° C e control

GLS01 / 3

GLS29 / 3 (-20 ° C option) and GLS29 / INT / 2

options included

Since this option emits heat, this must be taken into account during installation.

-40 ° C e control

GLS01 / 4

GLS29 / 4 (-40 ° C option) and GLS29 / INT / 2 Options included

Since this option emits heat, this must be taken into account during installation.

Interface for GLS90

GLS80 /, click below

·          F


 

 

 

 

GLS80 / 1

 

GLS80 / 2

 

GLS80 / 3

 

GLS80 / 4

 

GLS80 / 5

 

Pre-equipment required to connect the GLS90 dehumidifier to the cab (available separately).

 

450 L'lik kabinler için

1000 L'lik kabinler için

1300 L'lik kabinler için

2000 L'lik kabinler için

2600 L'lik kabinler için

 

Humidity control in ambient conditions (only) the interval must be extended.

GLS90 / Please choose from below

·         A *

 

GLS90 / 1

GLS90 / 2

GLS90 / 3 An

essential desiccant required to maintain moisture control in or under ambient conditions. For working range See graph. 1

The cab must have a GLS80 interface.

Interface for GLS112

Please select GLS112 / INT / below

 

 

·          F

 

 

GLS112 / INT / 1 GLS112 / INT / 2 GLS112 / INT / 3 GLS112 / INT / 4 GLS112 / INT / 5

Pre-equipment required to connect the GLS112 dehumidifier unit to the cab (available separately).

 

for cabins 450 l.

for cabins 1000 liters.

for cabins 1300 l.

for cabins 2000 l.

for cabins 2600 l

 

Is required to extend the control of temperature and humidity range Ambient conditions

GLS112 / Please choose from below

·          A *

 

 

 

 

 

 

 

 

 

 

 

 

 

GLS112 / 1

 

 

GLS112 / 2

 

 

GLS112 / 3

This is an air conditioning unit that controls the climatic conditions in the passenger compartment in the medium-sized environment in which it is located, without being tied to the cab.

for the working range. See graph 6 on page

 

For 450 l cabins

 

For cabins 1000/1300 liters.

For 2000/2600 liter cabins

As this variant emits heat, this must be taken into account during installation.

 

 

 

 

 

For all versions, the cabin must have a GLS112 / INT interface.

Interface for GLS29

Please select GLS29 / INT / below

·          F

 

 

 

 

GLS29 / INT / 1 GLS29 / INT / 2 GLS29 / INT / 3 GLS29 / INT / 4 GLS29 / INT / 5

Pre-equipment required to connect the GLS29 air conditioning unit to the cab (available separately).

for cabins 450 l.

for cabins 1000 liters.

for cabins 1300 l.

for cabins 2000 l.

for cabins 2600 l.

Cabins with this option do not have roof windows.

It is necessary to extend the temperature and humidity control range below freezing point.

GLS29 / Please select below

 

 

 

 

 

·          A *

 

 

 

 

 

 

 

 

GLS29 / 1

 

GLS29 / 2

 

GLS29 / 3

 

GLS29 / 4

 

GLS29 / 5

 

GLS29 / 6

 

Without cab connection, it is an essential air conditioning unit to extend the temperature and humidity control range. for the working range. 1 Graphics. See diagram on page.

 

 

 

-20 ° C block for 450 l cabins.

-40 ° C unit for 450 l cabins.

-20 ° C block for cabins 1000-1300 l.

-40 ° C unit for cabins 1000-1300 l.

-20 ° C unit for cabins 2000-2600 l.

-40 ° C unit for cabins 2000-2600 l.

See graph 1.

 

 

 

 

 

 

 

 

 

Since this unit emits heat to the environment, this must be taken into account during installation. For all versions the cab must have a GLS29 / INT interface

This is required for the SAEJ2334 test and some GM

GLS30.

·          F *

These are high level nozzles that spray salt directly vertically onto test specimens under programmed control. Separately, he sprays room temperature brine from a can.

 

 

 

OPTIONAL TEST CABIN ACCESSORIES

Function

Item Code

Definition

Remarks

For tests requiring fog moisture.

GLS32 ^

It allows you to spray water in the form of fog in high humidity conditions (95 -100% RH).

 

Interface for GLS34

GLS34 / INT ^

 

·          F

Preliminary equipment required to connect the GLS34 liquid immersion unit to the Cab. (available separately).

For GLS46 or GLS10 / 110 options

Required for liquid immersion tests.

GLS34 ^

 

·          A *

GLS34 is required by the User to automatically submerge test samples at the bottom level of the cabinet in salt water at a controlled temperature of + 50 ° C / + 122 ° F.

The cab must have a GLS34 / INT interface.

Required for wall wash tests.

GLS42 ^

·         “F

This is equipment that allows you to automatically spray water on the walls in the cabinet. The washing time and time can be programmed by the user.

 

Required for ASTM G85 annex A4 test.

GLS46 ^

 

 

 

 

·           “F

This is necessary to meet the requirements of the ASTM G85 annex A4 standard. The

optional accessory consists of a SO2 gas inlet and a level eliminator, the ratio and duration can be set by the user.

The user must provide the SO2 gas tube and fittings. This system is not intended for use with GLS01, GLS10, GLS20, GLS34 / INT and GLS92 equipment.

Required for multiple and multiple salt spray tests.

GLS86 ^

 

 

 

 

·         “F *

Each test allows different salt spray climates to be programmed separately within the program.

costs from additional salt solution, sprayers, etc.

 

 

  •         - Cyclic corrosion test booths

* - These accessories are not associated with booths and require cab connection and / or additional services. It also requires a space that it can position and a dedicated connection point to it. Detailed information is available upon request.

^ - Available in various sizes / specifications - more information on request.

«- Atmosfar cabins

A - Can be taken separately

F - Can only be assembled at the factory

We can manufacture equipment according to your technical specifications

Designed to meet the needs of
testing by manufacturing companies and
testing laboratories that need
corrosion tests, especially in aerospace,
defense and automotive industries.
corrosion testing with test booths
corrosion resistant performance in an accelerated laboratory environment.
Corrosion tests are performed on various
coating applications or used for testing
products used in the production of metal
alloys in various climatic conditions. According to type
dough cabinets, salt spray mist, condensation moisture,
soaking, drying air, controlled humidity,
cooling tests occur on the samples.
The cabins have been designed in volumes of 500 lt and 1300 l in
in accordance with the test objectives, in the temperature ranges
test environment from -40C to + 80C and with a test
environment with relative humidity up to 100%.
Testing standards are prepared with established
cockpit testing application library. The appropriate environment is ensured by selecting the test in
control module, and the testing process begins.

Do you want to buy a serial model of the Cab or order according to your own technical task?

Leave your details and our manager will contact you and agree on the terms of reference

Order equipment

We provide warranty and post-warranty service for testing equipment.