st. Danila Nechaya, 65/325
Heat-Cold-Moisture chambers (KTHV, KTV)
The heat-cold-moisture chamber is designed for testing in conditions of varying humidity from 20 to 98% RH, as well as at temperatures from -70 to +150 ˚C. Humidity and temperature in the chamber can not only change, but stabilize at specified conditions
Order equipment
Temperature range from -70ºC to + 150ºC with Maintenance accuracy 1ºC
Humidity range from 20 to 98% RH with an accuracy of 1 ... 3% RH
Touch screen control
Viewing window
Technological hole with a diameter of 100 mm
Possibility to move on built-in support rollers
CHARACTERISTICS | KTHV-150 | KTHV-300 | KTHV-500 | KTHV-800 | KTHV-1000 | KTHV-2000 |
---|---|---|---|---|---|---|
Chamber volume, l | 150 | 300 | 500 | 800 | 1000 | 2000 |
Useful volume size, WxHxD, mm | 500х500х600 | 600х700х700 | 800х800х800 | 900х900х1000 | 1000х1000х1000 | 1000х1300х1500 |
Overall dimensions, WxHxD, mm | 800х1750 х1050 | 980х1750х1500 | 1250х2100х1850 | 1400х2100х2000 | 1450х2200 х2100 | 1400х2300 х2700 |
Temperature range, ºC | -70...+150 | -70...+150 | -70...+150 | -70...+150 | -70...+150 | -70...+150 |
Temperature maintenance accuracy, ºC | ±1 | ±1 | ±1 | ±1 | ±1 | ±1 |
Humidity range,% RH | 20…98% | 20…98% | 20…98% | 20…98% | 20…98% | 20…98% |
Humidity maintenance accuracy,% RH | 1…3% | 1…3% | 1…3% | 1…3% | 1…3% | 1…3% |
Viewing window | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Technological hole, mm | 100 | 100 | 100 | 100 | 100 | 100 |
Mains voltage | 380V/50Hz/3F | 380V/50Hz/3F | 380V/50Hz/3F | 380V/50Hz/3F | 380V/50Hz/3F | 380V/50Hz/3F |
We can manufacture equipment according to your technical specifications
Description of equipment series KTHV, KTV
The heat-cold-moisture chamber is designed for testing in conditions of varying humidity from 20 to 98% RH, as well as at temperatures from -70 to +150 ˚C. Humidity and temperature in the chamber can not only change, but stabilize under specified conditions.
The useful volume chamber is made of corrosion-resistant steel, equipped with a swing door and a viewing window. A glass wiper is installed on the viewing window, which works when the glass is fogged up. As standard, the chamber is equipped with one removable shelf, but depending on the size of the working chamber, several shelves can be installed for more ergonomic placement of the test samples.
The two-stage chiller operates on ozone-safe refrigerants (freon R 404/503, R 23) and is air-cooled (standard) or water-cooled (optional).
The humidification system is a reservoir with water and heating elements. Heating is carried out using heat and electric heaters.
The camera is controlled by a touch screen with a human-readable interface, based on Russian or Japanese PLCs.
Each heat-cold-moisture chamber of the KTHV series is equipped with support rollers, a technological opening with a diameter of 100 mm, a removable shelf and lighting of the working volume.
Leave your details and our manager will contact you and agree on the terms of reference
Order equipmentWe provide warranty and post-warranty service for testing equipment.